電生理數據收集系統 Dendrite Data Acquisition system

產品型號: Dendrite
廠牌名稱: Sutter Instruments
您的實驗室擁有堪用的舊式的電生理記錄系統,但苦於再也沒有電腦能夠支援嗎?
Dendrite ™電生理數據收集系統是Sutter Instruments 最新研發的產品,可以將電生理訊號轉換成品質絕佳的數位訊號,並透過USB介面傳輸至電腦進行進一步的分析,更重要的是,Dendrite ™電生理數據收集系統支援市面上常見的大部分電生理設備品牌!若您需要利用有限的預算來延長舊式電生理設備的壽命,Dendrite ™是您的最佳選擇!

產品特點

產品特色

  • 包含了功能強大的SutterPatch® 記錄分析軟體,賦予您充足的數據記錄/分析彈性
  • 支援任何第三方廠牌的類比訊號輸入設備,包含了常見的舊式電生理訊號放大器
  • 安裝只需使用一條BNC線將放大器的類比訊號輸出至Dendrite,無需更動放大器與headstage既有的配線
  • 使用USB與電腦連接,無需專門的數據擷取介面卡與桌上型電腦
  • 日後可直接加價升級換購新款的dPatch 或 IPA電生理記錄系統,節省您未來汰舊換新的支出

The conventional architecture of an electrophysiology system follows a three-tier structure consisting of an amplifier, a computer interface, and data acquisition software. Sutter Instrument’s patch clamp amplifier systems, the IPA® Family and the dPatch® Amplifier systems combine these three tiers into convenient, fully integrated packages that include the increasingly popular SutterPatch® Data Acquisition, Management and Analysis Software. The Dendrite™ system meets the needs of customers who want to combine an existing amplifier with the functionality of SutterPatch software.

Featuring eight analog input signals, four analog output lines and eight digital outputs, at a sampling rate of up to 50kHz, the Dendrite system covers the majority of electrophysiology applications. Independent 16-bit A-D and D-A converters constitute state-of-the-art technology that avoids crosstalk and provides adequate resolution for virtually all use case scenarios. Trigger in- and output lines enable coordination with other equipment.

Connection to the computer is conveniently established through a High Speed USB 2.0 connection and the installation of drivers and SutterPatch software is typically completed within minutes. The Dendrite system accepts input from the majority of patch clamp and other electrophysiology amplifiers that comply with the common standard of +/-10 V signal range. It also controls amplifiers and peripherals that accept analog or digital input according to common standards.

 

SUTTERPATCH SOFTWARE

The Dendrite and SutterPatch software system has been engineered to let the user add information about instrument settings, stimulus application and external experiment parameters and associate them in time with the raw data traces. This includes all acquisition settings, as well as timing and progress of the experiment. In addition, the experimenter can manually trigger tags to document events like stimulus application in instruments not connected to the Dendrite system.

Information about environmental parameters and a more detailed specification of sample properties can be recorded and stored with the raw data. A total of over 600 metadata attributes are supported. Examples include: animal species, genotype, date/time when a cell sample was prepared, recording solutions, pipette resistance, hardware properties, and detailed information about stimuli applied.

 

DATA VISUALIZATION AND ANALYSIS

SutterPatch software has been designed to simplify the navigation and analysis of complex datasets. The scope window supports multiple view modes in both two-dimensional and an innovative three-dimensional display. The 3D view is particularly useful during assay development. Built on top of the latest version of the proven Igor Pro platform, SutterPatch combines native Igor Pro functionality with a wealth of features that are tailored to electrophysiology applications. Both the newcomer and the experienced user of patch clamp programs will feel comfortable using SutterPatch software.



Data Acquisition

  • High-speed USB connection controls data acquisition
  • Up to 8 analog input channels (±10 V; 0.1–50 kHz sampling rate per channel)
  • 4 analog output channels (±10 V)
  • 8 digital output channels (TTL)
  • Up to 400 kHz aggregate sampling rate
  • Complex command waveforms
  • Data acquisition can be initiated by an onboard microsecond clock or external (TTL) trigger

SutterPatch® Software

  • Built on the foundation of Igor Pro (WaveMetrics, Inc.)
  • Paradigms and Routines provide complete experimental control
  • Waveform Editor for easy creation of even the most complex stimulus patterns or user-defined templates
  • Associated metadata stores all relevant information regarding your experiment
  • Comprehensive data analysis routines and publication-quality graphics
  • Rapid-response online line-frequency reduction
  • Runs on Windows 10 or later (64-bit), or Macintosh OS X 10.11 (El Capitan)

Application modules provide focused functionality for particular applications.

  • Event Detection Module: A deconvolution algorithm that excels at detecting miniature synaptic events even on a noisy background
  • Action Potential Analysis Module: Phase plane plot, timing and waveform statistics
  • Camera Module: An easy way to document the identity and condition of the recorded cell
  • Single-channel Analysis Module: All-points histogram, idealized trace, duration and amplitude distribution and scatter plot


Screenshot of SutterPatch Software

產品規格

TECHNICAL SPECIFICATIONS

Dimensions
TBA
Weight
TBA

Electrical
110/240 Volts
50/60 Hertz power line

SYSTEM REQUIREMENTS

  • Minimum Configuration:
  • Windows 10 (64-bit), or MacOS: 10.11, El Capitan or later
  • Processor: Dual-core i5
  • Memory: 3 GB
  • Hard Disk: 500 GB or greater
  • Display Resolution: 1024 x 768 (XGA)
  • 1 available USB 2.0 High Speed port
  • Recommended Configuration:
  • Windows 10 (64-bit), or MacOS: 10.11, El Capitan or later
  • Processor: Dual-core i5
  • Memory: 8 GB
  • Solid-state drive (SSD): 500 GB or greater
  • Display resolution 1920 x 1080 (Full HD)
  • 1 available USB 2.0 High Speed port

SUTTERPATCH® Data Acquisition Management System and Analysis Software: Included with all Sutter Instrument Amplifier Systems

Notes:
USB 3.0 ports are compatible with USB 2.0 High Speed specifications.
Slower USB 2.0 ‘full-speed’ ports, which are sometimes found on older Windows PCs or USB add-in cards, are not supported.

To check for High Speed USB 2.0 or USB 3.0 on a PC computer running Windows, look in the Control Panel > Device Manager > Universal Serial Bus controllers section for “Enhanced” host controllers. As this does not provide any mapping information to the computer’s physical ports, and there can be a mix of USB port versions, you should check individual USB ports for USB 2.0/3.0 High Speed operational performance. As a visual indicator, USB 3.0 ports are often color coded blue.

USB hubs are not supported. USB add-in cards, even if they formally meet High Speed or Super Speed specifications, are not recommended. They are often architecturally configured as USB hubs and may lead to intermittent transfer errors that are hard to troubleshoot.

Operating systems installed within virtualization software platforms such as VMware and Parallels are not supported.