STARR MouseOx Plus 小動物生命特徵監測儀

產品型號:
廠牌名稱:
無創
適用於麻醉和意識受測者
成體到幼體均適用
MRI兼容
可用於監測多個受試者

產品特點

MouseOx Plus Small Animal Vital Signs Monitor

  • Non Invasive
  • Works on anesthetized and conscious subjects
  • Works on neonates through adults
  • MRI Compatible (see MouseOx Plus sensors)
  • Can be used to monitor multiple subjects (see Multiplexer)


 

Q: What is the difference between the MouseOx® and MouseOx Plus®?
A: The MouseOx Plus® uses the same pulse oximetry technology as the original MouseOx® but also includes several significant improvements. The MouseOx Plus® has enhanced signal processing ability that improves response to the motion of conscious subjects. The pulse signal is maintained during more significant movement and the SpO2 signal is re-acquired more quickly following significant movement. The MouseOx Plus® has a modular software design that allows the end user to purchase only the functionality that is needed. Measurement of core body temperature is now available with the MouseOx Plus®. The MouseOx Plus® can be used in conjunction with our multiplexers in order to monitor up to 8 animals with temperature, or 16 animals without temperature, using 1 MouseOx Plus.

Q: Will the MouseOx®/MouseOx Plus® work with both mice and rats?
A:Yes. There are 16 variations of the MouseOx® sensor available to accommodate various sensor placement options on mice and rats weighing from 1 to 500+ grams.

Q: What is the size range of mice and rats that can be used with the MouseOx®/MouseOx Plus®?
A: The MouseOx® works on mice and rats ranging in size from neonatal mice to rats over 500gm. The subject must have a heart rate of at least 90 BPM and no greater than 900 BPM.

Q: Does the MouseOx®/MouseOx Plus® work on animals other than mice and rats?
A: The MouseOx® is being used in many research projects on subjects other than mice and rats. Some examples include tree shrews, voles, Guinea pigs, hamsters, rabbits and small primates such as marmosets. (Note: The MouseOx® oxygen saturation measurement has only been validated with mice and rats.)

Q: Will the MouseOx®/MouseOx Plus® work on subjects with non-white fur?
A: Yes, the MouseOx® works on subjects with all colors of fur. The sensor location may need to be shaved on animals with dark fur. The MouseOx® may have difficulty obtaining measurements on subjects with very darkly pigmented skin.

Q: Does the MouseOx®/MouseOx Plus® need to be connected to any other equipment in order to function?
A: The MouseOx® must be connected to a Windows computer with a USB 2.0 port and running the latest version of the MouseOx® software. MouseOx® also requires wall outlet power.

Q: Can I run MouseOx®/MouseOx Plus® on an Apple/Mac computer?
A: Yes, with the use of a Windows® emulator such as Parallels Desktop©.

Q: How does the MouseOx®/MouseOx Plus® calculate arterial oxygen saturation?
A: The MouseOx®, like all pulse oximeters, directly measures the absorption of light by hemoglobin, which varies depending on the degree to which oxygen is bound to hemoglobin. Since 97% of oxygen is carried to the tissues by hemoglobin, arterial oxygen saturation is a very good indicator of cardio-pulmonary status.(Note: pulseoximetry does not measure PaO2)

Q: How often do I need to calibrate the MouseOx®/MouseOx Plus®?
A: The MouseOx® has been calibrated at the factory, and does not require any further calibration. Calibration data is contained within the software so you must not use a software revision earlier than that which was supplied at the time of purchase.

Q: What is the expected range of oxygen saturation for anesthetized and awake mice?
A: Normal saturation for mice and rats should be in the range of 95-97%. This range should be the same for both anesthetized and awake animals as long as anesthesia is administered properly. Awake animals at rest may have oxygen saturation as low as 90% for various reasons such as huddling in a corner of their habitat which can cause re-breathing.

Q: How many subjects can the MouseOx®/MouseOx Plus® monitor at a time?
A: The MouseOx® is limited to monitoring/recording one subject at a time. The Multiplexer for the MouseOx Plus® enables you to monitor up to 16 subjects, one at a time, with only one MouseOx Plus®.

Q: Has the MouseOx®/MouseOx Plus® ever been used in any studies that have been published?
A: Yes, the MouseOx® has been referenced in hundreds of peer-reviewed publications. http://starrlifesciences.com/?q=publications

Q: Has the MouseOx®/MouseOx Plus® ever been validated?
A: Yes. Click here for a link to our validation paper http://starrlifesciences.com/sites/default/files/WhitePaper.pdf

Q: What are Pulse Distention and Breath Distention?
A: Pulse Distention is a measure of the change in volume of the blood vessels in the sensor light path due to local blood pressure changes induced by the beating of the heart. Breath Distention is a measure of the change in volume of the blood vessels in the sensor light path due to local blood pressure changes induced by the change of intrathoracic pressure associated with breathing.

Q: How does the MouseOx®/MouseOx Plus® obtain the respiratory rate from the sensor?
A: The MouseOx is sensitive enough to measure the blood volume variations in the sensor light path due to variations of intrathoracic pressure. From this measurement we can determine both breath distension and breath rate.

Q: What is the purpose of the analog output on the MouseOx Plus®?
A: An analog pulsatile waveform generated from the raw infrared light signal is output to the BNC connection on the outside of the MouseOx Plus enclosure. This signal can be monitored and recorded for further analysis or used in gating applications.

應用領域

Provides the following measurements:

-Arterial Oxygen Saturation
-Heart Rate
-Breath Rate
-Temperature*
-Pulse Distention
-Breath Distention
-Activity (Optional)