產品資訊
產品資訊
微探針用體溫計 BAT-12 Microprobe Thermometer
產品型號:
廠牌名稱: Physitemp
We designed the world’s first thermocouple thermometer, Model BAT-4, in 1969. It soon found uses in the lab, factory, hospital O.R. and in the field. The new BAT-12 has improvements for all these applications:
In the lab: Readings to 0.1° C; near perfect stability.
In the field: A superior’cold junction reference’which maintains accuracy with ambient temperature changes from O°C to 50°C; sealed construction, carrying case.
For recording: Analog output for strip chart recording is a standard feature.
BAT-12 is the ideal instrument for use with microprobes. These 5 sensors are among our most popular and there are many more to choose from:
We designed the world’s first thermocouple thermometer, Model BAT-4, in 1969. It soon found uses in the lab, factory, hospital O.R. and in the field. The new BAT-12 has improvements for all these applications:
In the lab: Readings to 0.1° C; near perfect stability.
In the field: A superior’cold junction reference’which maintains accuracy with ambient temperature changes from O°C to 50°C; sealed construction, carrying case.
For recording: Analog output for strip chart recording is a standard feature.
BAT-12 is the ideal instrument for use with microprobes. These 5 sensors are among our most popular and there are many more to choose from:
* Flexible Implantable Microprobe, IT-18
* Needle Microbrobe, MT-26/2
* Surface Probe, BT-1
* General Purpose Probe, HT-1
* Sensor Six Pack, PT-6
* Flexible Implantable Microprobe, IT-18
* Needle Microbrobe, MT-26/2
* Surface Probe, BT-1
* General Purpose Probe, HT-1
* Sensor Six Pack, PT-6
產品特點
BAT-12 reads to 1/10°C |
Super Accuracy and Fast Readings |
Auto Corrected for Ambient Temperature |
Heavy duty carrying case |
Analog output |
產品規格
Specifications
|
||
Temperature Range | -100°C to +200°C | |
Resolution | 0.1° | |
Accuracy | 0.1°C ± 1 digit between 0-50°C 0.1% ± 1 digit over full range |
|
Calibration Conformity | Follows NIST thermocouple tables within 1 digit Ambient Temperature |
|
Compensation | Auto-compensated to 0.1°C from 0°C to 50°C | |
Readout | 3 1/2 digits, 1/2" liquid crystal numerals | |
Input Socket | Miniature, quick disconnect, copper-constantan | |
Analog Output | lOmV per degree C, approx. | |
Power Supply | Model BAT-12 9V transistor battery, available everywhere Model BAT-12R AC 115V and Ni-Cad battery with charger |
|
Size, Weight | 5" x 2 1/2" x 6" - 2 lbs., including carrying case |
Optional Accessories
|
Type T Thermocouple Probes |